XPS/XCT SERIESTRANSDUCERSXPS/XCTTRANSDUCERSInstruction Manual June 2002
Page 8 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Mounting - Liquid Applications (cont’d) Flange, gasket and hardware supplied by customer. R
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 9Interconnection blk/hotwht/shldFor EnviroRanger ERS 500 only, connect all three wires separ
Page 10 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Dos and Don’ts Installation shall only be performed by qualified personnel and in accorda
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 11Applications The transducer is to be used only in the manner outlined in this instruction
Page 12 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Liquid Applications - Submergence In applications where flooding is possible the transduce
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 13Liquid Applications - StandpipesIn many applications access must be made via a standpipe.
Page 14 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Liquid Applications - Volume 1. Beam should not detect bin bottom. If this occurs use rang
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 15Liquid Applications - Water / Wastewater Differential LevelPump Control Sewage Lift
Page 16 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Solids Applications - Typical 13452bin wall seamsfilling profileemptying profile1. Transdu
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 17Solids Applications - Special 213infeeddrag conveyortypical high leveltypical low level5.
© Siemens Milltronics Process Instruments Inc. 2002Safety GuidelinesWarning notices must be observed to ensure personal safety as well as that of oth
Page 18 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Installation DiagramTOLERANCES UNLESS OTHERWISE NOTEDANGLE S FRACTIONS APPROVED BYCHECKED
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 19For Canadian Hazardous Installation OnlyNOTES :2) A SEAL SHALL BE INSTALLED WITHIN 50 mm O
IQ300IX.fm Page 5 Tuesday, October 2, 2001 1:43 PM
IQ300IX.fm Page 5 Tuesday, October 2, 2001 1:43 PM
*7ml19981ak01*Rev. 1.4
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 1General InformationRefer to this manual for proper installation, operation, and maintenance
Page 2 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01General GuidelinesXPS/XCT Series - Certificate SIRA 99ATEX5153X This equipment may be used
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 3These devices should only be supplied from a circuit containing a suitably rated fuse that
Page 4 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Specifications Model : XPS - 10 XPS - 15 XPS - 30 XPS - 40 XCT - 8 XCT - 12Measurement Ra
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 5Outline and DimensionsModel Dimension XPS 10 XPS - 15 XPS - 30 XPS - 40 XCT - 8 XCT -
Page 6 XPS/XCT Transducers– INSTRUCTION MANUAL 7ML19981AK01Mounting Dos and Don’ts Special handling precautions must be taken to protect the face of t
7ML19981AK01 XPS/XCT Transducers– INSTRUCTION MANUAL Page 7Mounting - Liquid Applicationsflexible conduitsteel channelcouplingtransducerFlexible condu